About 50 results
Open links in new tab
  1. Navien NPE-240A and NaviCirc Installation Question

    Oct 25, 2021 · Hello, I just had my Navien NPE-240A (EDIT: It's actually an NPE-240A2) and NaviCirc installed today. First time tankless user. I was reviewing the manual and installation after they left, …

  2. Navien NCB-240E Pressure Dropped - Love Plumbing & Remodel

    Oct 15, 2018 · So my Navien had a code E351 along with the ranch sign on. I called Navien support and was told to read the PSI after I plug out and in the system. PSI was 4.1. They told me to call a …

  3. Navien NPE-240A Recirculation Question - Love Plumbing & Remodel

    Mar 5, 2022 · Hi all, we had a Navien NPE-240A installed in 2014, and have been happy with it. We did have a weird issue with water temperature being colder than expected occasionally, but it always …

  4. Navien NCB manifold piping - Love Plumbing & Remodel

    May 28, 2019 · The heat exchanger in the Navien is a water tube type with a high pumping head, and isn't designed for high flow rates, but also requires a minimum flow rate to avoid microboil on the …

  5. Navien NPE240A- Navilink,Navilink App, Recirculation settings And ...

    Jan 15, 2020 · Navien NPE 240A— Navilink recirculation—some customer insights. I have had The Navien NPE240A for about two years now and the unit has worked flawlessly, but it has taken me a …

  6. E010 on Navien with solution and report on my problems over 4 years

    Jul 9, 2015 · Ok, So I have a 4.5 year old Navien NR-210a condensing tankless heater. (Late 2010) I more or less did the entire install myself with the help of a few skilled friends either on site or on the …

  7. Navien 240A recirculating line - Love Plumbing & Remodel

    Jan 11, 2021 · The Navien NaviCirc manual specifies on page 10, the appropriate P.17 setting is ON, but NaviCirc is a thermostatic valve utilized when there is not a dedicated return line so the home's …

  8. Navien 240A Revving Noise - Love Plumbing & Remodel

    Jan 25, 2021 · Hello, hoping people here can help with a loud Navien 240A revving sound. Replaced two tanks that had a continuous circulation pump on dedicated copper recirculation line with a new …

  9. How to Bleed Air from Navien Combi 240? - Love Plumbing & Remodel

    Jan 8, 2019 · How to Bleed Air from Navien Combi 240? Hope Jan 8, 2019 navien ncb-240e combi boiler pressure drops slowly

  10. How to properly use / configure Navien hydronic system

    Jan 1, 2022 · Hi, Should a Navien hydronic heating system turn on and off four to five times an hour? I am living in a place with a Navien CH-240 that drives domestic hot water and an in-floor, six-zone …